No Products in the Cart
The Troxler nuclear moisture density gauges are used by many contractors, engineers, and highway departments for compaction control of soil aggregate, concrete, and full depth asphalt. The gauges meet or exceed the ASTM standards D6938, D2950, and C1040. The operator selects the density measurement mode, backscatter, or direct transmission based on the material type and the thickness of the layer being measured.
These updated gauges offer new standard features and many optional new features. The owner can customize the gauge to meet their testing needs.
The Model 3430 is the simplest and most economical gauge offered by Troxler. This gauge offers many features, including:
Optional features for the Model 3430 include:
The Model 3440 is for users who want user-friendly features. Along with the standard features provided in the Model 3430, the Model 3440 provides additional features including:
Optional features offered for the Model 3440 include:
Both models offer:
Measurement Specifications
Direct Transmission (150 mm) |
|||
|
.25 min |
1 min |
4 min |
Precision kg/m3 (pcf) |
±6.8 (±0.42) |
±3.4 (±0.21) |
±1.7 (±0.11) |
Composition error (kg/m3) (pcf) |
±20.0 (±1.25) |
±20.0 (±1.25) |
±20.0 (±1.25) |
Surface error (kg/m3) |
–17.0 (-1.25) |
–17.0 (-1.25) |
–17.0 (-1.25) |
Backscatter (98%, 100 mm) |
|||
Precision (kg/m3) (pcf) |
±16.0 (±1.0) |
±8.00 (±0.50) |
±4.00 (±0.25) |
Composition error (kg/m3) (pcf) |
±40.0 (±2.50) |
±40.0 (±2.50) |
±40.0 (±2.50) |
Surface error (kg/m3) |
-75.0 (-4.68) |
-75.0 (-4.68) |
-75.0 (-4.68) |
Surface error (kg/m3) |
-75.0 (-4.68) |
-75.0 (-4.68) |
-75.0 (-4.68) |
Moisture at 240 kg/m3 |
|||
Precision (kg/m3) (pcf) |
±10.3 (±0.64) |
±5.1 (±0.32) |
±2.6 (±0.16) |
Surface error (kg/m3) |
-18.0 (-1.12) |
-18.0 (-1.12) |
-18.0 (-1.12) |
Mechanical Specifications
Gauge Size (including handles) |
12” - 23.5”x9”x14.5” |
Shipping Case Size |
29.4” x 13.9” x 16.5” |
(75cm x 35cm x 42cm) |
|
Shipping Weight |
83lbs (37.6kg) |
Weight |
31lbs (14.1kg) |
Operating Temperature |
32º to 122º F (0º to 50º C) |
Surface |
350°F (175°C) for 15 minutes |
Storage Temperature |
0º to 140º F (-18º to +60º C) |
Radiological Specifications
Gamma Source |
0.30 GBq (8mCi) ± 10% Cs-137 |
Neutron Source |
1.48 GBq (40mCi) ± 10% Am-241:Be |
Source Housing |
Stainless steel, encapsulated |
Surface Dose Rate |
(5cm) 19 mrem/hr maximum, neutron and gamma |
Shipping Case |
DOT 7A, Type A, Yellow II label, TI=0.3 |
Electrical Specifications
Main Power Source |
5C NiMH (Rechargeable Pack) |
Backup Power Source |
5 AA Alkaline Batteries – 3440 |
Stored Power |
4 Ampere hours |
Battery Recharge Time |
3 hours maximum, auto cutoff |
Charge Source |
110/220 VAC, 50 or 60 Hz or 12-14 VDC |
Current Consumption Average |
35 mA |
Time Before Auto Shutdown |
5 hours of inactivity |
Readout |
4 x 20 Alphanumeric |
Keypad |
30 key sealed membrane – 3440 |
Model 3430 Options:
Model 3440 Options: