No Products in the Cart
16 kN measurement capacity apparatus is used for determining of bond/pull-off strength of repair mortar, hardened rendering, plastering, etc.
EN 1015-12, 1348, 1542, 12616-2, 13963, 14496
The apparatus is basically a dynamometer fitted with a load cell and high resolution digital display unit. The direct tensile force is applied by rotating the hand wheel.
UTC-3254 |
Drill bit with centering point to obtain, 50 mm dia. test surface |
---|---|
UTC-3256 |
Drill bit with centering point to obtain, 20 mm dia. test surface |
UTC-3257 |
Metal ring (dinking die), 50 mm int. dia, 25 mm high, for fresh plaster, to EN 1015-12 |
UTC-3258 |
Aluminium Test Disc, 50 mm dia |
UTC-3260 |
Aluminium Test Disc, 20 mm dia. |
UTC-3262 |
Test square plate, aluminium, 50x50mm, conforming to EN 1348 |
UTC-3264 |
Serial Cable for PC connection |
UTC-3266 |
Stainless steel test disc 50mm dia. x 20mm thickness. (conforming to EN 1015-12) |
UTC-3268 |
Adhesive Bicomponent. 2x15ml binder and 2x15ml hardener (4 vials) |
Load capacity |
16 kN |
---|---|
Readout unit |
Load cell |
Resolution |
10 N |
Working range |
0.25 to 16 kN |
Accuracy |
better than ± 1% |
Battery |
9 V |
Dimensions |
340x240x250 mm approx. |
---|---|
Weight |
5 kg with carrying case, 3.3 kg tester only |